  max. ac 5000a power measuring instruments clamp on power hitester 3 1 69 -20, 3 1 69 -21 flexible clamp on sensor 9667 measures power lines of up to 254 mm in diameter offering a new approach to energy-related measurement such as energy conservation, iso14001 testing, equipment diagnosis, and harmonics measur ement. the photo shows the 3169 - 21 combined with clamp on sensors 9661 and 9669 (optional) for measuring two systems. the 3169 - 20/21 can also be used in combination with clamp on sensors (optional) rated up to 5000 a. clamp on power hitesters are 3169 - 20 and 3169 - 21 that allow measurement of single-phase to three-phase 4-wire circuits with a single unit. in addition to measuring standard parameters such as voltage, current, power, power factor, and integrated values, these clamp-on power meters can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurements. the two new power meters also feature pc card data storage, and come equipped with an rs-232c interface for pc communications. further, with greater data processing speeds, it is possible to measure the power of just a few cycles, enabling more detailed and effective energy-saving measures for equipment. the 3169 - 20 and 3169 - 21 are ideal for users who want to achieve close control over energy-saving management activities and measures. measure up to two 3-phase, 3-wire systems (displays voltage and current for three lines) measure up to four single-phase, 2-wire systems 0.5 a to 5000 a range compact and light weight pc card data storage power recording for individual waveforms simultaneous recording of demand values and harmonics power measurement support software 9625
measure power lines of up to four systems (with a common voltage) one single unit can measure four circuits (single-phase 2-wire), two circuits (3-phase, 3-wire), or a one circuit (3-phase, 4-wire)system. a wide range of measurement functions the 3169 - 20/21 can simultaneously measure voltage, current, power (active, reactive, and apparent), integrated power, power factor, and frequency. further, when using 3-phase, 3-wire (3p3w2m) mode, you can display the voltage and current for all three lines by measuring just two of them. when using the 3-phase, 4-wire (3p4w4i) mode, neutral line current can be displayed using 4 current measurement. housed in a compact a5 body size the 3169 - 20 and 3169 - 21 feature a compact design that makes them portable and easy to use in tight spaces, and are approximately 30% more compact than the clamp on power hitester 3166 . multi-language compatibility select from nine languages, including japanese and english. detect incorrect connection using vector diagrams use the vector display on the connection confirmation screen to check the phase, whether a connection is loose, or whether the clamp-on sensor connection has been reversed during vt/ct terminal measurement. high-speed d/a output the 3169 - 21 comes equipped with 4-channel high-speed d/a output to enable analog output of rms values for individual waveforms. pc card compatible plus internal hard drive for extra memory store valuable measurement data in convenient pc cards. the internal memory (1 mb) supports measurement over extended periods and detailed measurement parameters. ideal for power and harmonics management the power meters come equipped with a harmonics measurement function that supports measurement of 3-phase power lines. they can also perform simultaneous measurement of harmonics and demand values, enabling both power and harmonics management. equipped with ranges from 0.5 a to 5000 a the power meters support seven types of clamp-on current sensors to enable measurement for a variety of items, from ct terminals to large current and thick power lines. polarity display and measurement using the reactive power measurement method the units come equipped with a polarity display for checking lag/ lead when measuring power factor or reactive power. further, you can select the reactive power measurement method, or display the phase factors for rms values and power comparison. clamp on power hitester 3169 -21 (shown with d/a output) offering a new measurement method for energy saving activities voltage cord 9438 -03 (4 provided) all in a compact a5-size unit simultaneous measurement of two 3-phase, 3-wire systems. select the clamp-on sensor type most suited to your measurement needs for each individual circuit. simultaneous recording of a variety of signal and energy-saving data. allows high-speed data transfer to a pc card for each waveform or at intervals of 0.1, 0.2, or 0.5 second. example of use in combination with four clamp on sensor 9661 (optional) features supports high-speed data storage from individual waveforms when using the standard mode to perform integrated power measurement, you can store data in intervals starting from one second, and when simultaneously measuring integration and harmonics, in intervals starting from one minute. when in the fast mode, you can store rms data for individual waveforms. clamp on sensor 9661 (500 a ac) clamp on sensor 9669 (1000 a ac) (optional) 1
2 the ultimate in clamp-on power meters! note 1: the range configuration table displays the full-scale display values for each measurement range. note 2: in the table, "unit w" has been replaced with "va" or "var" for the apparent- power and reactive power measurement ranges. note 3: voltage and current input values 0.4% or less than the measurement range are displayed as "zero". when either the voltage or current for the power line is zero, the power value is displayed as zero. note 4: you can display measurement values up to 130% of each measurement range. current (clamp on sensor) input terminal voltage ( voltage cord 9438 -03 ) input terminal sleek design and engineering the photo shows the 3169 - 21 with d/a output. d/a output terminal external i/o terminal rs-232c port contrast adjust volume power switch power inlet pc card slot external i/o terminal pin placement use the connection cable 9440 to connect to external devices. range configuration table key lock switch clamp on sensor 9669 150.00v single-phase 2-wire 15.000kw 30.000kw 150.00kw single-phase 3-wire 30.000kw 60.000kw 300.00kw 300.00v three-phase 3-wire three-phase 4-wire 45.000kw 90.000kw 450.00kw single-phase 2-wire 30.000kw 60.000kw 300.00kw single-phase 3-wire 60.000kw 120.00kw 600.00kw three-phase 3-wire three-phase 4-wire 90.000kw 180.00kw 900.00kw 600.00v single-phase 2-wire 60.000kw 120.00kw 600.00kw single-phase 3-wire 120.00kw 240.00kw 1.2000mw three-phase 3-wire three-phase 4-wire 180.00kw 360.00kw 1.8000mw 100.00 a 200.00 a 1.0000ka flexible clamp on sensor 9667 500.00 a 5.0000ka 150.00v single-phase 2-wire 75.000kw 750.00kw single-phase 3-wire 150.00kw 1.5000mw 300.00v three-phase 3-wire three-phase 4-wire 225.00kw 2.2500mw single-phase 2-wire 150.00kw 1.5000mw single-phase 3-wire 300.00kw 3.0000mw three-phase 3-wire three-phase 4-wire 450.00kw 4.5000mw 600.00v single-phase 2-wire 300.00kw 3.0000mw single-phase 3-wire 600.00kw 6.0000mw three-phase 3-wire three-phase 4-wire 900.00kw 9.0000mw pin signal name 1 start/stop input 2 free 3 status output pin signal name 1 d/a output ch1 2 d/a output ch2 3 d/a output ch3 4 d/a output ch4 5 to 8 gnd use the connection cable 9441 to connect to external devices. (output resistance: 100 ) d/a output terminal pin placement voltage connection current voltage connection current clamp on sensor 9695 - 02 (cat ii i 300v) clamp on sensor 9661 (5a, 10a, 50a, 100a, 500a) 150.00v single-phase 2-wire 75.000 w 150.00 w 750.00 w 1.5000kw 7.5000kw 15.000kw 75.000kw single-phase 2-wire 150.00 w 300.00 w 1.5000kw 3.0000kw 15.000kw 30.000kw 150.00kw 600.00v single-phase 2-wire 300.00 w 600.00 w 3.0000kw 6.0000kw 30.000kw 60.000kw 300.00kw three-phase 3-wire ( cat ii i 300v) (500ma, 1a, 5a) clamp on sensor 9694 ( cat ii i 300v) (5a, 10a, 50a, 100a) clamp on sensor 9660, 9695 - 03 500.00ma 1.0000a 5.0000a 10.000a 50.000a 100.00a 500.00a single-phase 3-wire 150.00 w 300.00 w 1.5000kw 3.0000kw 15.000kw 30.000kw 150.00kw three-phase 4-wire 225.00 w 450.00 w 2.2500kw 4.5000kw 22.500kw 45.000kw 225.00kw three-phase 3-wire three-phase 3-wire single-phase 3-wire 300.00 w 600.00 w 3.0000kw 6.0000kw 30.000kw 60.000kw 300.00kw three-phase 4-wire 450.00 w 900.00 w 4.5000kw 9.0000kw 45.000kw 90.000kw 450.00kw single-phase 3-wire 600.00 w 1.2000kw 6.0000kw 12.000kw 60.000kw 120.00kw 600.00kw three-phase 4-wire 900.00 w 1.8000kw 9.0000kw 18.000kw 90.000kw 180.00kw 900.00kw 300.00v pin 4 5 signal name data storage input gnd (500ma, 1a, 5a, 10a, 50a) current voltage connection
the addition of a vector display for viewing the connection status completes the preparation required for measurement. when measurement accuracy is crucial 3 promises reliable measurement for power demand requirements! select from a variety of data, including detailed and harmonics data for multiple circuits measure hidden power waste through secure connections, simple measurement methods, and detailed data capture. using the external i/o function, you can obtain even more detailed measurements for energy conservation. in addition to measurement start/stop control through external input, you can use this function to output the measurement start/stop signal for the 3169- 20/21 . simultaneous recording of a variety of signals is also possible for equipment when using multiple devices to perform start control and multi-channel recording. measure another device simultaneously 3169 -20 memory hicorder 3169 -20 master control synchronous with master simultaneous operation simultaneous control for signals from equipment the basic settings are constantly displayed, allowing you to measure with confidence. during measurement, in addition to displaying the voltage and current ranges, and vt (pt) and ct ratios for each system, the unit can also display items such as the measurement interval. because the basic settings are constantly visible, you can be confident of obtaining the correct measurement results. a single unit can measure two three-phase, 3-wire systems. further, you can make individual clamp-on sensor and current range settings for each system. also, in addition to performing simultaneous measurement for up to four systems (single-phase, 2-wire) with a common voltage, you can set the current range individually for each system. setting the most suitable current range for both large and small loads allows you to acquire more accurate measurements. to measure multiple systems simultaneously using the flexible clamp on sensor 9667 , you can measure power lines that are up to 5000 a ac and up to 245 mm in diameter. having trouble clamping onto thick power lines? 254mm (10.0") range: ac 500a/5000a power supply: 4 aaa alkaline batteries (lr03) (continuous use:one week or longer) or the ac adapter 9445 -02/03 have you ever experienced incorrect measurement results? the most common cause of incorrect data is a faulty connection. with the 3169 - 20/21 you can use the vector display to check the phase, whether a connection is loose, or whether the clamp-on sensor connection has been reversed. also, you are assured of proper connection when measuring the vt (pt)/ct terminals even if you cannot see the line you are measuring. checking the connection on the vector display accurate and reliable results by using continuous processing to measure individual waveforms, you can accurately measure data in a relatively short amount of time. use the desired measurement method to continuously measure the voltage, current, and power for individual waveforms, enabling you to obtain accurate data in one second or less. further, you can record the maximum, minimum and average values. capture facility data quickly measurement for up to four single-phase, 2-wire systems measurement for up to two three-phase, 3-wire systems use a single unit to simultaneously measure data for power and harmonics. all acquired data can be saved onto a pc card. simultaneous power and harmonics management power data (including demand data) and harmonics data can be simultaneously saved onto a pc card or in the unit's internal memory. further, data for all of the systems being measured can be saved when measuring multiple circuits. each of these two new unit's offers a management system for power and harmonic quality. use the 9669 sensor to measure two systems use the 9661 sensor to measure a single system the flexible clamp on sensor 9667 ability to measure power lines with good phase characteristics carrying up to 5000 a ac and measuring up to 254 mm in diameter allows you to measure the power for large current lines that were previously difficult to measure, such as trunk lines at factories.
4 greater flexiblity for energy saving measures through detailed measurement! large storage capacity to accommodate power and harmonics data for individual waveforms.-supports energy saving measures that can be carried out from your pc. harmonics cause wasted power did you think that harmonics and energy saving activities were unrelated? due to a spread in equipment that uses semiconductor control devices, such as inverters, power quality has decreased. also, power consumed in harmonic components is all wasted power. harmonic control and management are essential for energy conservation. to identify causal factors with harmonic measurements of multiple systems circuits if production equipment malfunctions, power is wasted if repeated manufacture results in defective products again. if you think harmonics are causing malfunctions, you can simultaneously measure the harmonics of individual circuits using multi-circuit measurement to obtain detailed information about the occurrence of harmonics along with the current direction for each phase. using the 3169 - 20/21 you can accurately determine the relationship for harmonic inflow and outflow between power lines by analyzing the data acquired simultaneously, and then devising energy-saving measures based on the cause of the occurrence. save measurement details to pc card for extended measurements! why not try a shorter data management interval? with the 3169 - 20/21 , you can set the data recording interval to 1 minute. if you are unsure how to proceed with energy conservation, you can use a large capacity pc card to save measurement details, then use the data to create a load fluctuation graph and analyze this to help reduce wasted power consumption. further, because you can save a variety of data, including simultaneous recording of power and harmonics data, waveform data storage, and print-outs of the screen, these two new units help by storing measurement details. identify even small amounts of power waste using individual waveform measur ement s the 3169 - 20/21 can help turn you into a keen energy saving specialist. these two new units allow you to measure power data by recording the rms values for individual waveforms. by measuring just a few seconds of machine cycles or changes in operating patterns of facilities such as manufacturing equipment, you can grasp power fluctuations over a relatively short amount of time and view improvements in the form of numerical data. gain unsurpassed energy savings by achieving simple improvements around the work environment. the current direction of harmonic waves is obvious the degree of distortion is obvious in the voltage/current display data storage 1p2w 4 1p3w 2 3p3w2m 2 3p3w3m,3p4w normal measurement (only saves average, integrated, and demand values) 85 days 106 days 100 days 171 days normal measurement (saves all items) 45 days 41 days 37 days 62 days normal measurement + harmonics measurement (saves all items) 37 hours 40 hours 30 hours 46 hours measurement conditions: 1-minute recording interval, when using a pc card (128 mb) interval 1p2w 4 1p3w 2 3p3w2m 2 3p3w3m,3p4w 1 minute 45 days (37 hours) 41 days (40 hours) 37 days (30 hours) 62 days (46 hours) 5 minutes 229 days (186 days) 205 days (203 hours ) 188 days (152 hours) 313 days (233 hours) 15 minutes 365 days (23 days) 365 days (25 days) 365 days (19 days) 365 days (29 days) 2 minutes 91 days (74 hours) 82 days (81 hours) 75 days (60 hours) 125 days (93 hours) 10 minutes 365 days (15 days) 365 days (16 days) 365 days (12 days) 365 days (19 days) 30 minutes 365 days (46 days) 365 days (50 days) 365 days (38 days) 365 days (58 days) measurement conditions: when saving all items using normal measurement, the number of days in parentheses indicate normal measurement + harmonics measurement, maximum measurement period of one year you can switch channels to easily check the harmonics for each circuit results can be easily processed using software such as excel. when using a 128 mb pc card reduce energy consumption by "1%" ! why not try analyzing your energy saving measures? when measuring 3p3w2m systems: displays the voltage/ current difference between each pair of lines and average values when measuring with 3p3w3m systems: displays the effective power for individual phases and the three- phase power values, as well as the voltage and current for all three lines unbalanced 3-phase loads can result in a damaged power line. to provide detailed management of measurements, the 3169 - 20/21 displays voltage and current for all three lines even when measuring just two circuits (3p3w2m). further, because the effective power for each phase is displayed based on a virtual center point when measuring the voltage and current for all three lines (3p3w3m), the units can also be used to implement energy saving measures and power management systems. unbalanced loads are an enemy to energy saving activities. solve your problems with careful management of power lines. improve energy-saving operations and create an energy-efficient facility why not try to improve your energy-saving measures using the 3169 - 21 ? using the d/a output (4 ch) function on the 3169 - 21 , you can simultaneously record a variety of measurement and control signals for equipment, such as the power fluctuation and temperature/flow for individual waveforms, onto a hioki memory hicorder or logger. a slight reduction in power consumption due to changes in the inverter motor operating patterns or temperature settings equals to an energy-saving effect. accurate recording of momentary fluctuations in power, etc. simultaneous recording of power volume the 3169 - 20/21 allows you to view changes that are hard to determine from numerical data alone.
easily display and print various screens such as graphs and spreadsheet tables 5 power measurement support software 9625 time series graph display function measurement data can be displayed as a time series graph. demand data measured in different series can be overlaid on the display. summary display function measurement data can be displayed directly in table form. features daily, weekly and monthly report display function daily, weekly and monthly reports of demand data can be displayed. harmonic analysis function display harmonic measurement data as a graph, list or waveform. (also compatible with the harmonic measurement data captured by model 3166 .) print function each screen can be printed. the power measurement support software 9625 application provides easy graphical processing on a computer of measurement data saved on clamp on power hitesters 3169 - 20/21 and 3166 . power data & harmonic data the 9625 handles both power and harmonic measurement data simultaneously. power data & harmonic data step 1. load measurement data load up to 16 data sets from the 3169 -20/21 or 3166 at once. measured numerical values and waveform data are recognized and displayed automatically. 1. loading and deleting data, and changing data names, can be done easily. 2. multiple sets of measurement data can be loaded and managed in a single file. step 2. select the display (screen) type select from time series graph, summary, daily, weekly or monthly report, harmonic list, harmonic graph, harmonic waveform or settings. step 3. select display items (two-axis display is possible) 1. select the data items (up to 16) to display. for graph displays, the type of graph (line or bar) can be selected. 2. enter details for data display. (data item names, levels, etc.) step 4. set the start/stop times and data interval to be displayed 1. set the data period to display. (start/stop time and data interval) ? the displayed period can be easily changed by scrolling. graphically process measurement data from model 3169 - 20/21 easily on a pc! 3166 3169 -20/21
harmonic waveform display displays the voltage and current waveforms upon which harmonic data is based. 6 the displayed graph can be set to suit particular start/stop times and data intervals. harmonic time series graphs can be displayed. convenient functions (1) the horizontal (time) axis can be easily scrolled to show the desired range. (2) upper and lower limits (measurement values) of the vertical axis can be easily set and changed. * graph type (line, bar or stacked bar), line type (such as solid or dashed), color and details of upper and lower numerical values can be set. (3) any desired numerical data value on a graph can be confirmed and displayed by cursor movement. (4) the display can be switched between 2d and 3d graphs. summary displays a summary of the data values between specified start/ stop times, at the specified data interval. convenient functions (1) in addition to measurement values within the period being displayed, the summary shows period, maximum, minimum and average values. (2) measurement data names and measurement units can be edited in the summary. daily, weekly or monthly report display displays a summary covering the total values in daily, weekly or monthly reports. convenient functions (1) the time axis for each total scrolls to easily change the totalized period. (2) the total time range of measurement data can be totalized in up to four sections per time period. harmonic display function harmonic data measured by the 3169 -20/21 and 3166 can be displayed in various ways harmonic list display displays harmonic data for the selected display item as a list. harmonic graph display displays harmonic data for the selected display item as a bar graph. summary display function time series graph display function (two-axes display possible) upper/lower limit setting slider cursor value view the power graph to confirm trends in harmonics view the waveforms to confirm distortion conditions simultaneously display multiple orders to confirm changes in harmonics! simultaneously display data from multiple instruments to confirm concurrent series of harmonics! view the list to confirm details harmonic time series display while displaying a time series graph, select the harmonic item for the vertical axis to display a time series graph of harmonics. convenient functions (1) up to 32 graphs can be displayed simultaneously using 2-axes display. for one circuit measurement, up to 32 orders can be graphed. using multiple instruments, time series of harmonics can be easily compared. (2) any desired chronological detail can be easily confirmed using the cursors on the graph.
3169 - 20/21 : 3169 - 20 , 3169 - 21 and 3166(clamp on power hitesters) : computer: pc-at compatible (dos/v machine) cpu: pentium 200 mhz or higher memory: 128 mb or more (recommended) hard disk: 128 mb or more free space display: xga (1024 768) or higher disc device: cd-rom drive (for installation) operating system: windows 2000, xp (english edition) supported instrument models operating environment 7 general specifications : display set standard value : line, bar, 2-axes and 3-dimensional : line type and display color can be set for each data set, and marker display is possible : up to 16 types of data series (demand value, demand quantity ) can be displayed in an overlay graph : measurement values can be displayed by the cursor : engineering units (m, k, m, g, etc.) can be selected reference value setting graph type selection graph line type & color setting stacked bar graph display cursor measurement data display units setting saved data /setting file extension data format 9625 combined file dat binary 9625 specifications [data/setting load/save functions] functional specifications : up to 528 mb per data set (total composite data up to 1.5 gb) : voltage, current, active power, reactive power, apparent power, power factor, frequency, integrated value(active power, reactive power), demand, harmonic (level, content ratio, phase angle, total value, thd) : the display position (upper and lower display limits) of the vertical (y) axis of a graph can be set by scroll bar or by specifying values. : select each cycle, or 0.1, 0.2, 0.5, 1, 2, 5, 10, 15 or 30 sec.; 1, 2, 5, 10, 15 or 30 min.; or 1, 2, 3, 4, 6, 8 or 12 h; or 1 day : an optional analysis period can be specified from the overall measurement data period (1) analysis start date and time (ymd, hms) is specified numerically (2) analysis stop date and time (ymd, hms) is specified numerically display of measurement data period (measurement start and stop date and time) maximum data capacity [time series graph display function] graph display item y-axis upper/lower limit setting interval setting display period range setting when you select a data name to be load, the measuring instrument model and setting conditions at measurement time are displayed. measurement data and measurement conditions can be managed at the same time. reports and screen copies of the displayed screen can be easily printed. convenient functions (1) printing results can be confirmed by print preview. (2) when creating a report, screen data can be copied and pasted into a commercial word processor program. print function settings display function preview printing to confirm print results before printing : one cd-r disc supplied media produce daily, weekly or monthly reports by one-touch report printing graph copying is also a one-touch operation loading data /setting file extension data format data contents data file csv csv instantaneous value, average value, maximum value, minimum value, integrated value, demand value, harmonic waveform data file wui binary instantaneous waveform short-interval data file bin binary instantaneous values 3166 integrated measurement data file itg csv instantaneous value, integrated value demand measurement data file dem csv instantaneous value, maximum value, minimum value, demand value harmonic measurement data file hrm csv instantaneous value, average value, maximum value waveform data file wui binary instantaneous waveform setting file set C 9625 combined file dat binary
8 : select the items to display in the summary : displays a report for the specified daily weekly or monthly period : calculates the load factor and demand factor as a daily, weekly or monthly report, and displays the results : specify up to four time ranges and totalize data for each time range independently : display the integrated active power (kwh) in co 2 according to the conversion rate. : displays waveform data for a specified time : displays a list of harmonic data for a specified time : display a bar graph of harmonic data for a specified time : displays the value at the cursor with waveform and graph displays : displays a list of the setting conditions loads setting conditions from a data file ( 3169 -20/21 ) loads setting conditions from a settings file ( 3166 ) [summary display function] display item selection daily, weekly and monthly report display load factor calculation display independent time range totalizing co 2 conversion display [harmonic display function] waveform display list display graph display cursor measurement [setting display function] setting display : each display can be copied to the clipboard : previews and prints the contents displayed on a tim e series graph : previews and prints the contents displayed in a summary : previews and prints the contents displayed in a harmonic spreadsheet : previews and prints the contents displayed in the settings display : text comments can be entered in any printout : any color or monochrome printing supported by the operating system : english : time-series graph ; summary ; daily,weekly and monthly report; harmonic waveform [copy function] copies to the clipboard [print function] printing a displayed time series graph printing a displayed summary printing a harmonic display printing the settings display comment entry printing support [display language] language [csv format conversion function] convertible screens 3169 - 20/21 specifications : single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and three-phase 4-wire systems (50/60 hz) : single-phase: 1p2w . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 systems 1p3w . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 systems three-phase: 3p3w2m (measures the voltage and current for two lines) . . . . . . 2 systems 3p3w3m (measures the voltage and current for all three lines) . . . 1 system 3p4w (measures the voltage and current for three lines) . . . . . . . . 1 system 3p4w4i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 system (measures the voltage for three lines and the current for four lines) : voltage, current, active power, reactive power, apparent power, power factor, integrated value, frequency, harmonics : for the voltage, current, and active power ranges, see the range configuration tables on page 2. : simultaneous digital sampling of voltage and current, pll synchronization or a fixed clock (50/60 hz) : voltage: isolated input current: isolated input using a clamp-on sensor : within 5 to 110% of the range : voltage and current: within 0.4 to 130% of the range (zero is suppressed for less than 0.4%) power: within 0 to 130% of the range (zero is suppressed when the voltage or current is zero) harmonic level: within 0 to 130% of the range : 5.7-inch lcd (320 240 dots), with backlight : manual (the current range can be set for each system) : approx. every 0.5 seconds (except when using a pc card while accessing the internal memory, or when performing rs-232c communications) : voltage: 2.0 m 10% (differential input) current: 200 k 10% : voltage input: 780 vrms ac, peak value: 1103 v current input: 1.7 vrms ac, peak value: 2.4 v : voltage input terminals: 600 vrms ac (50/60 hz) : voltage: less than 2 (for full-scale input) current: less than 4 (for full-scale input. however, less than 2 for the 500 a, 1 ka, and 5 ka ranges) : 1mb measurement line type number of systems that can be measured (for systems that share the same voltage) item measurement range measurement method input methods effective measurement area total display area display range switching method display update rate input resistance (50/60 hz) maximum input maximum rated voltage to earth crest factor internal memory capacity instantaneous value display average value display maximum/minimum value display integrate display demand volume display (integrated value within the specified interval) demand value display (average value within the specified interval) maximum demand value display (average value within the maximum specified interval) harmonics list harmonics graph waveform display measurement value enlargement display : voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current, (average values are for each system) : voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current * the average value from the beginning of time series measurement until the present. : voltage, current, active power, reactive power, apparent power, power factor, frequency * the maximum/minimum value from the beginning of time series measurement until the present. : integrated value active power (consumption/regeneration) reactive power (lag/lead) * the total integrated value from the beginning of time series measurement. : integrated value active power volume (consumption/regeneration) reactive power volume (lag/lead) * the integrated value within each specified interval (latest value). : active power (consumption), reactive power (lag), power factor * the demand value within each specified interval (previous value). : the maximum demand value since the beginning of time series measurement and the time and date it occurred. : list of the items measured for the specified harmonic (numerical value). (including the total value and total harmonic distortion factor (thd-f/thd-r)) : bar graph or vector diagram of the items measured for the specified harmonic. (cursor measurement, magnification update, with a linear/log axis selection function) : voltage and current waveforms (with a magnification update function) : select and enlarge up to 5 items from the instantaneous value display. basic specifications : 40.000 to 70.000 hz : within 10 to 110% of the range (for sine wave input) : voltage u1 : active power : 0.00000 mwh to 99999.9 gwh consumption -0.00000 mwh to -99999.9 gwh regeneration reactive power : 0.00000 mvarh to 99999.9 gvarh lag -0.00000 mvarh to -99999.9 gvarh lead : active power : displays consumption and regeneration separately reactive power : displays lag and lead separately : basic wave frequency: 45 to 66 hz pll synchronization : up to the 40th order : a single cycle (number of data points analyzed: 128 points) : rectangular : 1/16 cycles : harmonic level: the voltage, current, or power level for each harmonic order : harmonic content percentage: the voltage, current, or power content percentage for each harmonic order : harmonic phase angle: the voltage, current, or power phase angle for each harmonic order : total value: the total value for voltage, current, or power up to the 40th harmonic order : total harmonic distortion factor: for voltage or current (thd-f or thd-r) [frequency measurement] measurement range input area for guaranteed accuracy measurement source [integrated measurement] measurement range measurement display [harmonic measurement] measurement range measurement method order for analysis window width window type analysis rate item for analysis measurement specifications display specifications : true rms method : measurement of three voltage lines and 3 or 4 current lines is possible when using three-phase 3-wire and three-phase 4-wire systems : for three-phase 3-wire (the 3p3w3m setting), refer to the display for phase power values. : for consumption: no symbol, for regeneration: "-" : on: measures the reactive power directly using the reactive power measurement method off: calculates the reactive power from the measurement values for voltage, current, and active power : for lag phase (lag : current is slower than voltage): no symbol for lead phase (lead: current is faster than voltage) : "-" (reactive power measurement method "on") : no polarity : -1.0000 (lead) to 0.0000 to +1.0000 (lag) : for lag phase (lag: current is slower than voltage) :no symbol for lead phase (lead: current is faster than voltage) : "-" : 40.000 to 70.000 hz : within 10 to 110% of the range (for sine wave input) : voltage u1 [voltage/current measurement] measurement method measurement display [active power measurement] measurement display polarity display [reactive power measurement] using the reactive power measurement method polarity display [apparent power measurement] polarity display [power factor measurement] measurement range polarity display [frequency measurement] measurement range input area for guaranteed accuracy measurement source
[setting contents] measurement line settings clamp-on sensor settings vt (pt) and ct ratio settings measurement start method measurement stop method output interval data output destination file name display averaging circuit screen copy destination display language settings other settings [file operations] copy file load/save selected file delete file format storage format : 1p2w, 1p3w, 3p3w2m, 3p3w3m, 3p4w, 3p4w4i : 9694, 9660, 9661, 9667, 9669, 9695- 02 and 9695- 03 (* a different sensor can be set for each system.) : 0.01 to 9999.99 (* a different ct ratio can be set for each system.) : manual or time (year, month, day, hour, minute) : manual, time, or timer (1 seconds to 8784 hours) : standard or fast ( * maximum measurement period: 1 year) standard interval: 1, 2, 5, 10, 15, or 30 seconds, or 1, 2, 5, 10, 15, 30, or 60 minutes fast interval: a single waveform, or 0.1, 0.2, or 0.5 seconds : pc card, internal memory, or printer : automatically attached, or set the desired name (up to 8 alphanumeric characters) : off, 2, 5, 10, 20 times (for movement averaging) : pc card, internal memory, or printer : japanese, english, german, french, italian, chinese (simple, trad), spanish , korean : reactive power measurement method selection, harmonic distortion selection, order display selection, backlight settings, id settings, clock settings, etc. : copies files from the internal memory to the pc card. : loads/saves the file(s) selected from the internal memory or pc card. : deletes the file(s) from the pc card. : initializes the pc card or internal memory. : measurement data: csv format (binary format when using the fast interval setting) waveform data: binary format screen data: bmp format settings data: csv format 9 setting specifications : voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current, (average values are for each system) * the instantaneous value for interval output. : voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current, (average values are for each system) * the average value for each interval. : voltage, current, active power, reactive power, apparent power, power factor, frequency * the maximum/minimum value for each interval (no event details provided). : active power (consumption/regeneration) reactive power (lag/lead) * the total value since the beginning of time series measurement, and the power volume for each interval. : active power (consumption), reactive power (lag), power factor * the value for each interval. : the maximum demand value since the beginning of time series measurement and the time and date it occurred. : each harmonic order (level, content percentage, and phase angle), total value, instantaneous value for thd-f/thd-r : each harmonic order (level, content percentage, and phase angle), total value, average value for thd-f/thd-r for each interval : each harmonic order (level, content percentage, and phase angle), total value, maximum/minimum value for thd-f/thd-r within each interval (no event data provided) : waveform (voltage or current) : exceeds the voltage/current crest factor, pll unlock, power failure, exceeds the display limit : prints the data selected as the data output item (during time series measurement). : hard copy of the screen (printing of each interval not available) [data output item] instantaneous values average value maximum/minimum value integrated value demand value maximum demand value harmonic waveform status information [print items] numerical values waveform [d/a output] ( 3169 - 21 only) number of output channels output items output level resolution output accuracy temperature characteristic output resistance output update rate [pc card] [rs-232c] [external i/o] control input control output control signal level : 4 channels : for instantaneous values: voltage, current, average voltage, average current, active power, reactive power, apparent power, power factor, frequency for integrated value: active power (consumption/regeneration) or reactive power (lag/lead) for harmonics: each harmonic order (level, content percentage, and phase angle), total value, thd-f/thd-r : 5v dc/f.s. : polarity + 11 bits : measurement accuracy 0.2% f.s. : less than 0.02% f.s./ c : 100 5% : for each cycle of measurement input (when a measurement item other than harmonics is set) for every 16 cycles of measurement input (when harmonics is set as the measurement item) : slot: 1 pc card standard-compliant type ii card type: flash ata card compatible memory capacity: up to 528 mb storage content: settings data, measurement data, screen data : printer or pc connected to an rs-232c interface compliance: eia rs-232c-compliant transfer method: asynchronous communication method, full duplex baud rate: 2400, 9600, 19200, 38400 bps flow control and delimiter settings possible : start/stop control for time series measurement, data storage : low level is output during time series measurement. : a 0/5 v logic signal or a short-circuit/release contact signal conforming standards accessories : safety en61010 pollution degree 2, measurement category (anticipated transient overvoltage 6000v) : emc en61326 cla ss a en61000 - 3 - 2, en61000 - 3 - 3 : voltage cord set 9438 -03 (1) (1 cord each of black, red, yellow, and blue), voltage cord (1), input cord label (1), operating manuals (2) (advanced edition and quick start guide), cd-r (1) (advanced edition , rs-232c interface operating manuals and csv conversion software), connection cable 9441 (1) (for the 3169 -21 only) when using the reactive power measurement method: u : inter-line voltage i : line current m : number of samples s : sample count m : 128 samples per cycle when not using the reactive power measurement method: derives reactive power directly from voltage and current values, just as with the measurement of active power. (the same measurement principle is the same as that used to determine reactive power by large-volume power consumers.) calculates reactive power after calculating the apparent power using the voltage, current, and rms values. measurement is also possible using the reactive power measurement method in addition to conventional calculation methods that search for reactive power using voltage, current, and active power, you can select the reactive power measurement method, which derives reactive power directly from voltage and current values, just as with the reactive power volume measurement method used in large-volume power consumers. formulae (for single-phase 2-wire systems) external interface specifications operating environment operating temperature and humidity storage temperature and humidity withstand voltage (50/60 hz for 15 sec.) power supply voltage rating maximum rated power dimensions and weight : indoors, up to 2000m(78.74ft) asl : 0 to 40?c, 80% rh or less (non-condensating) : -10 to 50?c, 80% rh or less (non-condensating) : 5.55 kvrms ac: between the voltage input terminal and the 3169 casing 3.32 kvrms ac: between the voltage input terminal and the current input terminal/external interface terminal 2.3 kvrms ac: between the power supply and the 3169 casing 1.39 kvrms ac: between the power supply and the current input terminal/external interface terminal : 100 to 240 v ac, 50/60 hz : 30 va : approx.210(8.27 ? )w 160(6.30 ? ) h 60d(2.36 ? ) mm (excluding protrusions), approx.1.2 kg(42.3oz.) ( 3169- 20 , 3169 -21 ) general specifications
conditions of guaranteed accuracy te m p e r a t u r e a n d h u m i d i t y f o r guaranteed accuracy f u n d a m e n t a l w a v e f o r m r a n g e f o r guaranteed accuracy display area for guaranteed accuracy : after 30 minutes of warm-up, sine-wave input, pf=1 : 23?c 5?c, less than 80% relative humidity : 45 to 66 hz : effective measurement area 10 reference: accuracy of the clamp on sensore 9694,9695 -02 , 9695 -03 , 9660, 9661, 9667, and 9669 ? 9694 (rated for 5 a) : 0.3%rdg.0.02%f.s. ? 9695 -02 (rated for 50 a) : 0.3%rdg.0.02%f.s. ? 9695 -03 (rated for 100 a): 0.3%rdg.0.02%f.s. ? 9660 (rated for 100 a) : 0.3%rdg.0.02%f.s. ? 966 1 (rated for 500 a) : 0.3%rdg.0.01%f.s. ? 966 9 (rated for 1000 a) : 1.0%rdg.0.01%f.s. ? 966 7 (rated for 5000 a) : 2.0%rdg.1.5mv (500 a range: for 50 to 500 a input) (5000 a range: for 500 to 5000 a input) * f.s. is the sensor's rated primary current value. voltage current/active power 0.2%rdg.0.1%f.s. 0.2 % rdg. 0.1 % f.s. + clamp-on sensor accuracy table of current and active power accuracy with clamp-on sensor combinations note: the table of accuracy for different clamp-on sensor combinations indicates the measurement accuracy for each current range of the 3169 -20/21 . (the accuracy for each clamp-on sensor is converted and displayed according to the 3169 -20/21 current measurement range.) measurement accuracy (guaranteed accuracy period : 1 year) option specifications clamp on sensor 9694 9660 primary current rating ac 5 a ac 100 a 9661 9669 ac 500 a accuracy amplitude (45 to 66 hz) phase (45 hz to 5 khz) 0.3%rdg.0.02%f.s. 0.3%rdg.0.02%f.s. appearance within 2? within 1? frequency characteristic within 1.0% at 40 hz to 5 khz (deviation from accuracy) effect of external magnetic field equivalent to 0.1 a or less (with a magnetic field of 400 a/m ac) effect of conductor position within 0.5% 300 v rms (insulated conductor) maximum rated voltage to earth 300 v rms (insulated conductor) ac 1000 a maximum input (45 to 66 hz) 50 a continuous 130 a continuous measurable conductor diameter less than 15 mm(0.59") less than 15 mm(0.59") dimensions and weight 46w(1.81") 135h(5.31") 21d(0.83") mm, 230g(9.9oz.) 46w(1.80") 135h(5.31") 21d(0.83") mm, 230g(9.9oz.) 0.3%rdg.0.01%f.s. 1.0%rdg.0.01%f.s. within 0.5? within 1? within 2.0% at 40 hz to 5 khz (deviation from accuracy) 600 v rms (insulated conductor) 550 a continuous equivalent to 1 a or less (with a magnetic field of 400 a/m ac) less than 46 mm(1.81") within 1.5% 77w(3.03") 151h(5.94") 42d(1.65")mm, 380g(12.7oz.) 600 v rms (insulated conductor) 1000 a continuous less than 55 mm(2.17"), 80(3.15") 20 (0.79")mm bus bar 99.5w(3.92") 188h(7.40") 42d(1.65") mm, 590g(20.8oz.) output voltage ac 10mv/a ac 1mv/a ac 1mv/a ac 0.5mv/a clamp on sensor 9667 appearance primary current rating ac 500 a, 5000a output voltage ac 500 mv f.s. accuracy amplitude (45 to 66 hz) phase (45 hz to 5 khz) 2.0%rdg.1.5mv (for input 10% or more of the renge) power supply within 1? frequency characteristic within 3 db at 10 hz to 20 khz (deviation from accuracy) effect of external magnetic field equivalent to 5 a, 7.5 a max . (with a magnetic field of 400 a/m ac) effect of conductor position within 3.0% maximum rated voltage to earth 1000 v rms (insulated conductor) maximum input (45 to 66 hz) 10000 a continuous measurable conductor diameter less than 254 mm(10.0") dimensions and weight sensor: 910 mm(2.99ft) long, 240g(8.5oz.), circuit: 57w(2.24") 86h(3.39") 30d(1.18") mm, 140g(4.9oz.) lr03 alkaline battery 4 (continuous operation max. 168 hours) or ac adapter 9445 (optional) cat ii i 1000v cord length: sensor - circuit: 2 m(6.56ft) circuit - connector: 1 m(3.28ft) cat ii i 300v cat ii i 300v cord length: 3 m (9.84ft) cat ii i 600v cat ii i 600v cord length: 3 m (9.84ft) cord length: 3 m (9.84ft) cord length: 3 m (9.84ft) current rang 9660, 9695 - 03 9661 9669 9667 5a 0.5 % rdg. 0.5 % f.s. 0.5 % rdg. 1.1 % f.s. - - 10a 0.5 % rdg. 0.3 % f.s. 0.5 % rdg. 0.6 % f.s. - - 1a - - - - 50a 0.5%rdg.0.14%f.s. 0.5 % rdg. 0.2 % f.s. - - 100a 0.5%rdg.0.12%f.s. 0.5%rdg.0.15%f.s.. 1.2 % rdg. 0.2 % f.s. - 200a - - 1.2%rdg.0.15%f.s. - 500a - 0.5%rdg.0.11%f.s. - 2 .2 % rdg. 0.4 % f.s. 1000a - - 1.2%rdg.0.11%f.s. - 5000a - - - 2 .2 % rdg. 0.4 % f.s. 0.5a - - - - 9694 0.5%rdg.0.12%f.s. - 0.5 % rdg. 0.2 % f.s. - - - - - - 0.5 % rdg. 0.3 % f.s. 9695 - 02 0.5 % rdg. 0.3 % f.s 0.5 % rdg. 0.2 % f.s 0.5 % rdg. 1.1 % f.s 0.5%rdg.0.12%f.s. - - - - - 0.5 % rdg. 2.1 % f.s apparent power accuracy reactive power accuracy integration accuracy power factor accuracy frequency accuracy : 1 dgt. for the calculation obtained from each measurement value : when using the reactive power measurement method 0.2% rdg. 0.1% f.s. + clamp-on sensor accuracy when not using the reactive power measurement method 1 dgt. for the calculation obtained from each measurement value : 1 dgt. for the measurement accuracy of effective power, reactive power, and apparent power : 1 dgt. for the calculation obtained from each measurement value : 0.5% rdg. 1dgt. : fundamental waveforms up to the 50th order 3% f.s. + measurement accuracy (of a 45- to 66-hz fundamental waveform) : within 0.03% f.s./?c : within 0.2% f.s. (600 vrms ac, 50/60 hz, between voltage input terminal and case) : within 1.5% f.s. (in a magnetic field of 400 a/m rms ac, 50/60 hz) : 1.0% rdg. (45 to 66 hz, power factor = 0.5, for effective power measurement) : 1.0% rdg. (45 to 66 hz, reactive factor = 0.5, when using the reactive power measurement method) : 10 ppm 1 second (23?c) (within 1.9 sec/day (23?c)) frequency characteristic temperature characteristic effect of in-phase voltage effect of external magnetic field power factor influence effect of reactive factor real-time clock accuracy 9695 - 02 ac 50 a ac 10 mv/a within 2? 60 a continuous 9695 - 03 ac 100 a ac 1 mv/a within 1? 130 a continuous within 1.0% at 40 hz to 5 khz (deviation from accuracy) 0.3%rdg.0.02%f.s. equivalent to 0.1 a or less (with a magnetic field of 400 a/m ac) within 0.5% 300 v rms (insulated conductor) less than 15 mm(0.59") 50.5w(1.99") 58h(2.28") 18.7d(0.74")mm, 50g(1.8oz.) option : connection cable 9219 cat ii i 300v cat ii i 300v
options clamp on sensor 9660 (ac 100a) clamp on sensor 9661 (ac 500a) flexible clamp on sensor 9667 (ac 5000a) clamp on sensor 9669 (ac 1000a) clamp on sensor 9694 (ac 5a) clamp on sensor 9695 - 02 (ac 50a) clamp on sensor 9695 - 03 (ac 100a) connection cable 9219 (for connection to the 9695 - 02 , 9695 - 03 ) clamp on adapter 9290 - 10 (ac 1500a) connection cable 9440 (for external i/o) rs-232c cable 9612 (for connection to a pc) printer 9442 ac adapter 9443 - 02 (for the 9442 , for europe) ac adapter 9443 - 03 (for the 9442 , for usa) rs-232c cable 9721 (for connection to the 9442 ) recording paper 1196 (25 m(82ft)/10 rolls, for the 9442 ) carrying case 9720 power measurement support software 9625 pc card 128m 9726 pc card 256m 9727 pc card 512m 9728 11 option specifications printer 9442 : thermal serial dot printing : 112 mm(4.41ft) : 52.5cps : ac adapter 9443 - 02/03 , or supplied nickel-metal hydride battery (approx. 3000 lines of printing when fully charged and used with the 9443 - 02/03 ) : approx.160w (6.30") 66.5h(2.62") 17d(0.67") mm, approx.580g(20.5oz.) print method paper width print speed power supply dimensions and weight when purchasing the printer 9442 , make sure you also purchase the rs-232c cable 9721 and ac adapter 9443 - 02/03 so that you can connect it to the 3169 - 20/21 . carrying case 9720 a soft type case for storing the 3169 - 20/21 and its accessories, such as the clamp-on sensors. : approx. 445w(17.52") 340h(13.39") 150d(5.91") mm, approx. 2.2 kg(77.6oz.) dimensions and weight current and power cannot be measured using the clamp on power hitester 3169 - 20/21 on its own. to perform current and power measurement, make sure you also purchase a clamp on sensor (9694, 9660, 9661, 9667, or 9669) (sold separately). use only pc cards (9726, 9727or 9728) sold by hioki. compatibility and performance are not guaranteed for pc cards made by other manufacturers. you may be unable to read from or save data to such cards. combination examples for single-phase 2-wire systems (one system) : 3169 -20 + 9660 (100a) 1 +9726 (128mb) for single-phase 3-wire systems : 3169 -20 + 9660 (100a) 2 +9726 (128mb) (one system/two single-phase 2-wire systems) for three-phase 3-wire systems (one system) : 3169 -20 + 9661 (500a) 2 +9726 (128mb) for three-phase 3-wire systems : 3169 -20 + 9661 (500a) 4 +9726 (128mb) (two systems/four single-phase 2-wire systems) for three-phase 4-wire systems (one system) : 3169 -20 + 9661 (500a) 3 +9726 (128mb) clamp on power hitester 3169 - 2 0 (supplied with the voltage cord 9438 - 03 (1), and power cord (1)) clamp on power hitester 3169 - 21 (with d/a output) (supplied with the voltage cord 9438 - 03 (1), connection cable 9441 (1) and power cord (1)) accessory specifications voltage cord 9438 - 03 (1 cord each of black, red, yellow, and blue, cord length: 3 m(9.84ft)) connection cable 9441 (d/a output cable, supplied with the 3169 - 21 ) max. 1500 a ac (continuous: 1000 a) measurable conductor diameter: bus bar : 55 mm(2.17"), width 80 mm(3.46") ct ratio: 10:1 *used for expanding the measurement ranges of the 9660 and 9661 sensors clamp on adapter 9290 - 10 cord length: 3 m(9.84ft) rs-232c cable 9721 cord length for connecting to the 9442 : 1.5 m(4.92ft) ac adapter 9443 - 02/03 for the 9442 photo: 9443 - 03 connection cable 9441 cord length: 2 m(2.65ft) for d/a output (supplied with the 3169- 21 ) connection cable 9440 for external i/o cord length: 2m(2.65ft) pc card 9726 to 9728 use only pc cards (9726, 9727, or 9728) sold by hioki. for connection to the 9695 - 02 , 9695 - 03 connection cable 9219 cord length: 3 m(9.84ft) head office : 81 koizumi, ueda, nagano, 386-1192, japan tel +81-268-28-0562 / fax +81-268-28-0568 e-mail: os-com@hioki.co.jp hioki usa corporation : 6 corporate drive, cranbury, nj 08512 usa tel +1-609-409-9109 / fax +1-609-409-9108 e-mail: hioki@hiokiusa.com distributed by all information correct as of nov. 29, 2006. all speci?cations are subject to change without notice. 3 169 e7-6ye-03p printed in japan shanghai representative of?ce : 1904 shanghai times square of?ce 93 huaihai zhong road shanghai, 200021, p.r.china tel +86-21-6391-0090, 0092 fax +86-21-6391-0360 e-mail: info@hioki.cn